TNT - Gen4 Series
Portable Appliance Tester
ProductsElectricalPortable Appliance Tester    
 My Order | Login | Register |
Pricing
TNT el $1096.00* 
TnT RCD $1271.00* 
TnT + $1627.00* 
My Order
*15% GST applicable
for sales within NZ
Contents
TnT el
Appliance tester with leakage test
Instruction user guide
Earth bond lead 1800mm
IEC to 3 PIN plug test lead 500mm
Carry bag & locking power lead
TnT RCD
Same as TnT el
In-built RCD test module & firmware
TnT +
Same as TnT RCD
WinPATS base software
Interface ports (scanner, printer & keyboard)
USB cable (for connection to PC)
Portable Appliance Tester
Simplified One Button Testing
Test Icons & Symbols on Large LCD
Large Fonts During Tests Showing Results & Progress
Flashing Test Fail Indicator
Mains/Input Polarity Test on Startup
Impact Resistant & Flame Retardant Casing
Built In Carry Handle
The TNT Gen4 is an easy to use, intuitive hand held Portable Appliance Tester (PAT), designed to test for electrical safety and accuracy of 240VAC rated appliances (including RCD results on specific models). Simple one button automatic testing makes this series fast and easy to use.
The TNT series allows operators to fully comply with the requirements of the AS/NZS 3760 Standard.
The large backlit LCD display shows easy to follow menus, meaningful icons & selectable test screens for simpler user operation.
'On-start' tests range from mains supply testing, connectivity check, polarity with flashing fail indicators (also when test has failed), through to user selectable options, e.g. RCD ramp current etc. Functions vary depending on model, but the flexibility of this series suits all levels of Industry. Advanced features include ability to extend some test functions/ times, e.g. the earth bond test to 30 seconds allowing operators to obtain proper contact with the earth of some appliances.

Tester Function Chart

TnT elTnT RCDTnT +
Meter Mode
Class I / Class II
Extension leads
Leakage Current
500V Insulation / 250V Insulation
RCD Testing 
Mains Supply Test
Power Measurement  
Data Connectivity to PC /
Laptop via on-board USB port
  
Printer Connectivity via laptop/PC  
WinPATS base software   
WinPATS software (optional)  
WinPATS software included for TnT+ Model
Tests Performed / Specifications
Mains Supply Test
  Checks Polarity and continuity of mains supply by LED indicators (A-N, A-E, and N-E). (Flashing Test Fail indicator)
CLASS 1 Earthed Appliance.
  Appliance Check:
Ensures appliance is plugged in and turned on.
Earth Bond Test: 200mA test current. Pass level less than 1.0Ω. Measurement: 0.01Ω to 10Ω.
Insulation Test: 500VDC / 250VDC. Pass level greater than 1MΩ. Measurement: 0.1Ω to 10MΩ. *See also Leakage Test.
CLASS 2 Double Insulated Appliance
 Appliance Check:Ensures appliance is plugged in and turned on.
Earth Bond Test: 200mA test current. Pass level less than 1.0Ω. Measurement: 0.1Ω to 10Ω.
Insulation Test: 500VDC / 250VDC. Pass level greater than 1MΩ. Measurement: 0.1Ω to 10MΩ. *See also Leakage Test.
Extension Leads
 Earth Bond Test: 200mA test current. Pass level less than 1Ω. Measurement: 0.01Ω to 10.0Ω.
Insulation Test: 500VDC / 250VDC . Pass level greater than 1MΩ. Measurement: 0.1Ω to 10.0MΩ.
Continuity/Polarity Test:250VAC check continuity and polarity of leads. Displays Pass/Fail.
Leakage Test *
 Leakage Current:0 to 30.0mA at 200 to 265V.
Earth Leakage Test: 240VAC Mains. Pass level 1, 2.5, 5.0mA leakage test levels with up to 10Amp load operation.
  Note 1: Pass level for CLASS 1 is 5mA, Pass level for CLASS 2 is 1 mA.
Note 2: Leakage test may be performed if for any reason a standard CLASS 1 or CLASS 2 is not possible.
RCD Test  
Meter Mode Function
Meter Mode ®, allows for quick and simple electrical measurements
e.g. measuring power consumption of a bar heater or drill to check the
ratings, test power/voltages on outlets around sites on different circuits,
confirm specifications etc.
Meter Mode features four discrete options
Volts
Amps
Watts
Volt / Amps
Electrical parameters are displayed on the large LCD screen as Volts in AC, Current in Amps, Power Measurement in Watts and VA in Volt/AMPS.
Meter Mode Volts
 Trip Current:2 to 500mA in 1mA steps. User selectable.
Trip Time:0 to 3,000ms at 01sec resolution.
Current Ramp Trip Test:0 to 500mA in 1mA increments.
Power Measurement
 Leakage Current:0 to 30.0mA at 200 to 265V.
Load Current:0.0 to 10Amp.
Voltage:200 to 265VAC.
Power Factor:0 to 1.
Apparent Power:0 to 2400VA, Power 0 to 2400W.
Meter Mode®
 Load Current:0.0 to 10Amp.
Voltage:200 to 265VAC.
Apparent Power:0 to 2400VA.
Power:0 to 2400W.
Legal and Where to Buy