Legionella Prevention
|
 
 
 
Legionella Prevention
  • There are more than 100 cases of Legionnaires Disease in New Zealand every year
  • The kit includes 3 types of temperature probe for maximum measurement versatility, a countdown timer...
  • and anti-bacterial wipes. All in an ABS carry case.

What is Legionnaires' Disease?

Legionnaires' Disease is a potentially fatal form of pneumonia. The cause of the disease is a bacterium called legionella pneumophila. Symptoms of Legionnaires' can include headache, diarrhoea, dry cough, drowsiness and delirium.

How is it caught?

Legionnaires' Disease is caught by inhaling small droplets of water suspended in the air which contain the legionella bacterium, e.g. spray from showers and taps.

What are the sources of legionella bacterium?

The legionella bacterium is found mainly in stagnant water, e.g. ponds and rivers or buildings containing cooling towers, evaporation condensers, air conditioning and industrial cooling systems, humidifiers, spa baths and hot and cold water systems.

Who is most at risk?

People most at risk are those over 45, diabetics, those who are already ill, particularly with chronic diseases or whose immune system is impaired. Smokers and heavy drinkers also have an increased susceptibility.How using a thermometer can help control legionella in water

How using a thermometer can help control legionella in water

Incorrect water temperature is a key risk factor for legionella growth. The legionella bacteria multiply in water at temperatures between 20 and 45°. A typical method of control is to store hot water above 60° and distribute it at above 55° (45° for retirement homes & early childhood education centres to prevent scalding). Cold water should be kept below 20°.

$ 346.00*

Legionnaires disease got its name from an outbreak of pneumonia during a 1976 convention of American Legionnaires.

It‘s believed to have spread from a hotel's air conditioning system.

 

Measurement Range:
-99.9 to 1372°C
Resolution:-99.9 to 299.9: 0.1° otherwise 1°
Accuracy:±(0.1% of reading + 0.4°)
Input Type:K-Type Thermocouple
Display:12mm LCD
Dimensions:128mm(L) x 56(W) x 25mm, 130gm
Battery:3 x AAA provides 1000Hrs of operation

 

  • Sharp point allows easy penetration for taking internal temperatures
  • Response time < 3 seconds
  • K-Type thermocouple - Max temperature 250°C, 3.3 x 130mm
HHK160 Penetration Probe
  • Ideal for stationary, hard or metallic surfaces, as small as 8mm
  • Response time < 0.5 seconds
  • K-Type thermocouple - Max 250°C, 8 x 130mm
HHK044 Ribbon Surface Probe
  • Measure or monitor fridges, freezers, ovens, water, air & curing concrete
  • Response time < 0.5 seconds
  • K-Type thermocouple, -60 ~ 250°C, 1m or custom lengths
  • 1.5mm x 1000mm or talk to us about custom lengths
HHK362 Exposed Junction Bead Probe
  • Set to 99 minutes, 59 seconds or 19 hours, 59 minutes
  • Pocket clip, footstand & magnetic holder. 1 x AAA battery included
  • Size: 63(W) x 63(H) x 15mm
806 105 Count Up/Down Timer
  • Single tub (70 Wipes)
  • Reduce the risk of cross-contamination
  • Pre-saturated with a broad spectrum bactericide solution
Probe Wipes Mini-Tubs - Single tub