PicoScope 2000 Series
|
 
 
PicoScope 2000 Series
  • 2 channel, 4 channel and MSO models
  • 6 instruments in one
  • Ultra-compact design
  • Up to 100 MHz bandwidth
  • Up to 128 MS buffer memory
  • Decode over 38 serial protocols as standard
  • USB connected and powered
  • Windows, Linux and Mac software

You can use your PicoScope 2000 Series as an advanced oscilloscope, spectrum Analyser, function generator, arbitrary waveform generator and protocol decoder out of the box. Mixed signal models also add a 16 channel logic Analyser. A complete electronics lab in one compact, low-cost, USB-powered unit.

The PicoScope 2000A models deliver unbeatable value for money and are ideal for education, hobby and field service use. In the lab the low cost allows one scope per person rather than having to share.

The PicoScope 2000B models have the added benefits of deep memory (up to 128 MS), higher bandwidth (up to 100 MHz) and faster waveform update rates. PicoScope 2000B models give you the performance to carry out advanced analysis of your waveforms. They are ideal for design, debug and serial decoding.

$963.00*

ModelPicoscope
Bandwidth
10 MHz
25 MHz
50 MHz
70 MHz
100 MHz
2 Channel
2204A
2205A
 
2206B
 
2207B
2208B
4 Channel
 
 
2405A
 
2406B
2407B
2408B
2 Channel MSO
 
 
2205A MSO
 
2206B MSO
2207B MSO
2208B MSO
Oscilloscope — vertical (analog inputs)
Bandwidth
10 MHz25 MHz50 MHz70 MHz100 MHz
Rise time (calculated)35 ns14 ns7 ns5 ns3.5 ns
Vertical resolution8 bits
Enhanced vertical resolutionUp to 12 bits
Input ranges±50 mV, ±100 mV, ±200 mV, ±500 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V±20 mV, ±50 mV, ±100 mV, ±200 mV, ±500 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V
Input sensitivity (10 vertical divisions)10 mV/div to 4 V/div4 mV/div to 4 V/div
Input couplingAC / DC
Input connectorBNC
Input characteristics1 MΩ ± 1% , 15 pF ± 2 pF1 MΩ ± 1% , 16 pF ± 1 pF
Analog offset range (vertical position adjustment)None±250 mV (20 mV to 200 mV ranges)
±2.5 V (500 mV to 2 V ranges)
±20 V (5 V to 20 V ranges)
Analog offset control accuracyN/A±1% of offset setting, additional to basic DC accuracy
DC accuracy±3% of full scale ±200 µV
Overvoltage protection±100 V (DC + AC peak)
Oscilloscope — vertical (digital inputs, MSOs only)
Input channels
16 channels (2 ports of 8 channels each)
Input connectors2.54 mm pitch, 10 x 2 way connector
Maximum input frequency100 MHz (200 Mb/s)
Minimum detectable pulse width5 ns
Input impedance200 kΩ ±2% , 8 pF ±2 pF
Input dynamic range±20 V
Digital threshold range±5 V
Overvoltage protection±50 V
Threshold groupingTwo independent threshold controls: Port 0: D0 to D7, Port 1: D8 to D15
Threshold selectionTTL, CMOS, ECL, PECL, user-defined
Port threshold accuracy±350 mV (inclusive of hysteresis)
Hysteresis< ±250 mV
Minimum input voltage swing500 mV pk-pk
Channel-to-channel skew2 ns typical
Minimum input slew rate10 V/µs
Oscilloscope — Horizontal
Maximum Sampling Rate
(real-time)
100 MS/s
200 MS/s
500 MS/s
500 MS/s
1 GS/s
1 GS/s
1 GS/s
Equivalent sampling rate
(ETS mode)
2 GS/s4 GS/s5 GS/s10 GS/s
Maximum sampling rate
(USB streaming)
1 MS/s9.6 MS/s
Shortest timebase10 ns/div5 ns/div2 ns/div1 ns/div
Longest timebase5000 s/div (approx 14 hours per waveform in chart recorder view)
Buffer memory (block mode)*8 kS16 kS48 kS32 MS32 MS64 MS128 MS
Buffer memory
(USB streaming mode)
100 MS (shared between active channels)
Waveform buffers10 000
Maximum waveforms per second200080 000
Initial timebase accuracy±100 ppm±50 ppm
Timebase drift±5 ppm / year
Sample jitter30 ps RMS typical20 ps RMS typical3 ps RMS typical
ADC samplingSimultaneous
* Maximum sampling rate and buffer memory are shared between active channels. On MSO models each group of 8 inputs counts as a channel. Maximum sampling rate on MSO digital channels is 500 MS/s.
Dynamic Performance
Crosstalk (full bandwidth)Better than 200:1Better than 300:1
Harmonic distortion< -50 dB at 100 kHz, full scale input, typical
SFDR
(100 kHz, full-scale input, typical)
> 52 dB±20 mV range: > 44 dB
±50 mV range and higher: > 52 dB
Noise< 150 μV RMS (±50 mV range)< 220 μV RMS (±20 mV range)< 300 μV RMS (±20 mV range)
Bandwidth Flatness
(at scope input)
(+0.3 dB, -3 dB) from DC to full bandwidth
Triggering
SourcesCh A, Ch B, Ch C, Ch D. Any MSO digital channel
Trigger ModesNone, auto, repeat, singleNone, auto, repeat, single, rapid (segmented memory)
Advanced TriggersEdge, window, pulse width, window pulse width, dropout, window dropout, interval, logic.Edge, window, pulse width, window pulse width, dropout, window dropout, interval, runt pulse, logic
Trigger types, ETSRising or falling edgeRising or falling edge (available on Ch A only)
Trigger sensitivity, real-timeDigital triggering provides 1 LSB accuracy up to full bandwidth
Trigger sensitivity, ETS10 mV p-p, typical, at full bandwidth
Maximum pre–trigger capture100% of capture size
Maximum post–trigger delay4 billion samples
Trigger re–arm time
in rapid trigger mode
N/A< 2 µs on fastest timebase< 1 µs on fastest timebase
Max. waveforms
in rapid trigger mode
N/A9610 000
Function Generator
Standard output signalsSine, square, triangle, DC voltage, ramp, sinc, Gaussian, half sine
Pseudorandom output signalsNoneWhite noise, PRBS
Standard signal frequencyDC to 100 kHzDC to 1 MHz
Sweep modesUp, down, dual with selectable start/stop frequencies and increments
TriggeringNoneFree-run or up to 1 billion waveform cycles or frequency sweeps. Triggered from scope trigger or manually.
Output frequency accuracyOscilloscope timebase accuracy ± output frequency resolution
Output frequency resolution< 0.02 Hz< 0.01 Hz
Output voltage range±2 V
Output adjustmentsAny amplitude and offset within ±2 V range
Amplitude flatness (typical)< 1 dB to 100 kHz< 0.5 dB to 1 MHz
DC accuracy±1% of full scale
SFDR> 55 dB @ 1 kHz full scale sine wave> 60 dB @ 10 kHz full scale sine wave
Output characteristicsFront panel BNC, 600 Ω output impedance
Overvoltage protection±20 V
Arbitrary Waveform Generator
Update rate1.548 MHz20 MS/s
Buffer size4 kS8 kS32 kS
Resolution12 bits
Bandwidth100 kHz>1 MHz
Rise time (10% to 90%)< 2 µs< 120 ns
Spectrum Analyser
Frequency RangeDC to analog bandwidth of oscilloscope
Display modesMagnitude, peak hold, average
Windowing functionsRectangular, Gaussian, triangular, Blackman, Blackman Harris, Hamming, Hann, flat top
Number of FFT pointsSelectable from 128 to half the available buffer memory in powers of 2, up to a maximum of 1 048 576 points
Math channels and Software filters
Functions−x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, freq, derivative, integral, min, max, average, peak, delay, duty
Software filtersHighpass, lowpass, bandpass, bandstop
OperandsA, B (input channels), C, D (input channels, 4-channel models only), T (time), reference waveforms, constants, pi, digital channels (MSO models only)
Automatic Measurements
Scope ModeAC RMS, true RMS, frequency, cycle time, duty cycle, DC average, falling rate, rising rate, low pulse width, high pulse width, fall time, rise time, minimum, maximum, peak to peak
Spectrum ModeFrequency at peak, amplitude at peak, THD dB, SNR, SINAD, SFDR, total power, average amplitude at peak, THD %, THD+N, IMD
StatisticsMinimum, maximum, average and standard deviation
Serial Decoding
Protocols1-Wire, ARINC 429, CAN, CAN FD, DALI, DCC, DMX512, FlexRay, Ethernet 10Base-T, USB 1.1, I²C, I²S, LIN, Manchester, MODBUS, PS/2, SPI, SENT, UART/RS-232 (subject to bandwidth and sampling rate of chosen oscilloscope model)
Mask Limit Testing
Mask generationNumeric (automatic) or Graphical (manual)
StatisticsPass/fail, failure count, total count
Available actions on mask failBeep, play sound, stop capture, save waveform, trigger signal generator / AWG, run executable
Display
InterpolationLinear or sin(x)/x
Persistence ModesDigital color, analog intensity, custom, fast or none
SDK / API details and specifications for customers writing their own software
Supplied drivers32 and 64-bit drivers for Windows 7, 8 and 10, Linux drivers, Mac OS X drivers
Example codeC, C#, Excel VBA, VB.NET, LabVIEW, MATLAB
Maximum USB
streaming sampling rate*
1 MS/s5 MS/s31 MS/s
Buffer memory
in USB streaming mode*
Limited only by PC
Segmented memory buffers*N/A96128000256000512000
* These specifications apply when using the drivers / writing your own software. Refer to Horizontal section above when using PicoScope software
General
Package contentsPicoScope 2000 series oscilloscope
2 or 4 switchable 10:1/1:1 oscilloscope probes (except for PicoScope 2204A / 2205A when purchased without probes)
TA136 digital cable (MSOs only)
2 x TA139 pack of 10 logic test clips (MSOs only)
USB cable, Quick start guide
PC ConnectivityUSB 2.0 (USB 3.0/3.1 compatible)
Power RequirementsPowered from USB port
Dimensions (including connectors)142 x 92 x 18.8 mm130 x 104 x 18.8 mm
Weight< 0.2 kg (7 oz)
Temperature range, operating0 °C to 50 °C
Temperature range, operating
for stated accuracy
15 °C to 30 °C
Temperature range, storage-20 °C to +60 °C
Humidity range, operating5% to 80% RH non-condensing
Humidity range, storage5% to 95% RH non-condensing
Altitude rangeup to 2000 m
Pollution degree2
Safety approvalsDesigned to EN 61010-1:2010
Pollution degree2
Environmental approvalsRoHS, WEEE
EMC approvalsTested to meet EN61326-1:2013 and FCC Part 15 Subpart B
Software
Windows software
PicoScope for Windows PicoSDK Software development kit (SDK). Windows 7, 8 or 10 recommended (read more)
macOS software
PicoScope for macOS Software development kit (SDK) OS versions: see release notes
Linux software
PicoScope for Linux Software development kit (SDK) See Linux Software & Drivers for details of supported distributions
    PicoScope 2000 Series oscilloscope
      4x switchable 10:1/1:1 oscilloscope probes
        USB cable
          Quick start guide