PicoScope 4444 kit
|
 
 
PicoScope 4444 kit
  • 4 fully differential high-impedance inputs
  • 20 MHz bandwidth
  • Flexible 12 and 14-bit resolution
  • 256 MS deep memory

We and our distributors supply three preconfigured kits with everything you need to get started with differential measurement. Each kit includes a PicoScope 4444 high-resolution differential oscilloscope and three differential voltage probes with Pico D9 connectors. The kits also come with a TA271 D9‑BNC adaptor, which lets you use traditional oscilloscope voltage probes and current probes, to make single-ended measurements with a ground-referenced probe. Finally, all three kits are delivered in a sturdy carry case

$5344.00*

Vertical
 Oscilloscope OnlyWith PicoConnect 442 1kV CAT III Probe
Input channels4 channels4 channels
Analog bandwidth (-3 dB)20MHz with D9-BNC adaptors
15MHz with PicoConnect 441 probe
10MHz
Rise time (calculated)17.5ns with D9-BNC adaptors
23.3ns with PicoConnect 441 probe
35ns
Bandwidth limiter100kHz or 1MHz (selectable)100kHz or 1MHz (selectable)
Vertical resolution, 12-bit mode12 bits on most input ranges
11 bits on ±10mV range
12 bits
Vertical resolution, 14-bit mode14 bits on most input ranges
13 bits on ±20mV range
12 bits on ±10 mV range
14 bits
Enhanced vertical resolution
(PicoScope 6 software), 12-bit mode
Up to 16 bits on most input ranges
Up to 15 bits on ±10 mV range
16 bits
Enhanced vertical resolution
(PicoScope 6 software), 14-bit mode
Up to 18 bits on most input ranges
Up to 17 bits on ±20mV range
Up to 16 bits on ±10mV range
18 bits
Input typeDifferential
9-pin D-subminiature, female
Differential
9-pin D-subminiature, female
Input characteristics1 MΩ ±1%, in parallel with 17.5pF ±1pF
(each differential input to scope ground).
<1pF difference between ranges.
16.7MΩ ±1%, in parallel with 9.3pF ±1pF
(each differential input to scope ground)
Input couplingAC or DCAC or DC
Input sensitivity2mV/div to 10V/div±0.5V/div to ±200V/div
Input ranges (full scale)±10mV, ±20mV, ±50mV, ±100mV, ±200mV, ±500mV,
±1V, ±2V, ±5V, ±10V, ±20V, ±50V
±2.5V, ±5V, ±12.5V, ±25V, ±50V, ±125V, ±250V, ±500V, ±1000V
Input common mode range5V on ±10mV to ±500mV ranges
50V on ±1V to ±50V ranges
125V on ±2.5V to ±12.5V ranges
1000V on ±25V to ±1000V ranges
DC accuracy (DC to 10 kHz)±1% of full scale, ±500µV±3% of full scale, ±12.5mV
Analog offset range±250mV on ±10mV to ±500mV ranges
±2.5V on ±1V to ±5V ranges
±25V on ±10V to ±50V ranges
±6.25V on ±2.5V to ±12.5V ranges
±62.5V on ±25V to ±125V ranges
±625V on ±250V to ±1000V ranges
Analog offset accuracy1% of offset setting in addition to basic DC accuracy1% of offset setting in addition to basic DC accuracy
Overvoltage protection±100V DC + AC peak (any differential input to ground)
±100 DC + AC peak (between differential inputs)
CAT III 1000V

Horizontal
Maximum sampling rate (real time)12-bit mode1 channel: 400MS/s
2 channels: 200MS/s
3 or 4 channels: 100MS/s
Maximum sampling rate (real time)
14-bit mode
50MS/s
Maximum sampling rate (USB streaming)16.67 MS/s
Shortest real-time collection time, 12-bit mode50 ns (5 ns/div)
Shortest real-time collection time, 14-bit mode200 ns (20 ns/div)
Longest real-time collection time50000 s (5000 s/div)
Capture memory (block mode)256 MS shared between active channels
Capture memory (USB streaming mode)100 MS (shared between active channels)
Waveform buffers10000
Collection time accuracy±50ppm (5ppm/year aging)
Sample jitter3ps RMS typical
ADC samplingSimultaneous sampling on all enabled channels


Dynamic Performance (Typical)
 Oscilloscope OnlyWith PicoConnect 442 1kV CAT III Probe
Crosstalk2000:1 DC to 20MHz2000:1 DC to 10MHz
Harmonic distortion at 100kHz, 90% of full scale< -70dB on ±50mV ranges and higher
< -60dB on ±10mV and ±20mV ranges
< -70dB
SFDR> 70dB> 70dB
ADC ENOB, 12-bit mode10.8 bits10.8 bits
ADC ENOB, 14-bit mode11.8 bits11.8 bits
Noise< 180µV RMS on ±10mV range< 5mV RMS on ±2.5V range
Bandwidth flatness(+0.1dB, -3 dB) DC to full bandwidth(+0.1dB, -3 dB) DC to full bandwidth
Common mode rejection ratio60dB typical, DC to 1MHz55dB typical, DC to 1MHz

Triggering
SourceAny input channel
Trigger modesNone, auto, repeat, single, rapid
Trigger typesEdge, window, pulse width, window pulse width, dropout, window dropout, interval, runt pulse, logic
Trigger sensitivityDigital triggering provides up to 1 LSB accuracy up to full bandwidth
Maximum pre-trigger captureUp to 100% of capture size
Maximum trigger time-delay4 billion samples
Trigger rearm time< 2µs on fastest timebase
Maximum trigger rate10 000 waveforms in a 12ms burst

Probe Compensation Pins
Output level4V peak
Output impedance610Ω
Output waveformsSquare wave
Output frequency1kHz
Overvoltage protection±10V

Spectrum analyzer
Frequency rangeDC to analog bandwidth of oscilloscope
Display modesMagnitude, average, peak hold
Windowing functionsRectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top
Number of FFT pointsSelectable from 128 to half available buffer memory in powers of 2, up to a maximum of 1 048 576 points

Math Channels
General functions−x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, derivative, integral, delay
Filter functionsLowpass, highpass, bandstop, bandpass
Graphing functionsFrequency, duty cycle
Multi-waveform functionsMin, max, average, peak
OperandsInput channels, reference waveforms, time, constants, pi

Automatic Measurements
Scope modeAC RMS, true RMS, frequency, cycle time, duty cycle, DC average, edge count, falling edge count, rising edge count, falling rate, rising rate, low pulse width, high pulse width, fall time, rise time, minimum, maximum, peak to peak
Spectrum modeFrequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD
StatisticsMinimum, maximum, average and standard deviation

Serial Decoding
Protocols1-Wire, ARINC 429, CAN, CAN FD, DCC, DMX512, Ethernet 10Base-T, FlexRay, I²C, I²S, LIN, PS/2, SENT, SPI, UART (RS-232 / RS-422 / RS-485), USB 1.0/1.1

Mask Limit Testing
Mask generationNumeric (automatic) or graphical (manual)
StatisticsPass/fail, failure count, total count
Available actions on mask failBeep, play sound, stop capture, save waveform, trigger signal generator / AWG, run executable

Display
InterpolationLinear or sin(x)/x
Persistence modesDigital color, analog intensity, custom, fast or none

SDK/API Details & Specifications for Users Writing their own Software (see “Horizontal” above for details when using PicoScope 6 software)
Supplied drivers32 and 64-bit drivers for Windows 7, 8 and 10
Linux drivers
Mac OS X drivers
Example codeC, C#, Excel VBA, VB.NET, LabVIEW, MATLAB
Maximum sampling rate (USB streaming)50MS/s
Capture memory (USB streaming)Up to available PC memory
Segmented memory buffers> 1 million

Software
Windows softwarePicoScope for Windows Software development kit (SDK) Windows 7, 8 or 10 recommended 
macOS softwarePicoScope for macOS Software development kit (SDK) OS versions: see release notes
Linux softwarePicoScope for Linux Software development kit (SDK) See Linux Software & Drivers for details of supported distributions

General Specifications
PC connectivityUSB 3.0, compatible with USB 2.0, USB 1.1
Power requirementsUSB port or external DC PSU, depending on connected accessories
Dimensions190 x 170 x 40mm including connectors
Weight< 0.5kg
Temperature range, operating0°C to 45°C
Temperature range, operating, for quoted accuracy15°C to 30°C
Temperature range, storage-20°C to 60°C
Humidity range, operating5% to 80% RH non-condensing
Humidity range, storage5% to 95% RH non-condensing
AltitudeUp to 2000 m
Pollution degreePollution degree 2
Safety approvalsDesigned to EN 61010-1:2010
EMC approvalsTested to EN 61326-1:2013 and FCC Part 15 Subpart B
Environmental approvalsRoHS and WEEE compliant
PC requirementsProcessor, memory and disk space: as required by the operating system Port(s): USB 3.0 or USB 2.0
  • 1000 V CAT III, passive differential probe
  • 25:1 10 MHz voltage measurement
  • Used with the PicoScope 4444 only
3x PicoConnect 442 1000 V CAT III passive differential voltage probes
    3x TA368 2000 2000 A AC flex current probes
    • Suitable for ground-referenced measurements
    • Essential when using the TA325 and TA326 current probes
    • Used with the PicoScope 4444 only
    1x D9-BNC adaptor
      USB 3.0 cable
      • Hold the PicoConnect 4444 and its accessories
      • Portable
      PicoScope 4444 carry case
        5 V AC power adaptor