subcategories
*15% GST applicable for sales within NZ
PicoScope 2000 Series
- 2 Channels + Arbitrary Waveform Generator
- Bandwidth 10 MHz, Rise Time 35 ns,
- Sampling Rate: 100 MS/s, Buffer Memory 8 kS

S1021 Oscilloscope Probe
- A good quality general purpose oscilloscope probe
- 1:1/10:1 Switchable, 20/150MHz Bandwidth
- 400/600Vpk. 1.8/2.3ns Rise Time
PicoVNA Vector Network Analyser
- 300 kHz to 6 GHz operation
- Up to 124 dB dynamic range at 10 Hz bandwidth
- 0.005 dB RMS trace noise at maximum bandwidth of 140 kHz

V6021 Oscilloscope Probe
- Attenuation = 1:100, Bandwidth = 300MHz
- Maximum Voltage = 1500Vp, Rise Time = 1.2ns
- One of two high voltage probes in the range. Both have enhanced BNC insulation.

V6041 Oscilloscope Probe
- Attenuation = 1:100, Bandwidth = 300MHz
- Maximum Voltage = 2500Vp, Rise Time = 1.2ns
- The second of two high voltage probes in the range. Both have enhanced BNC insulation

H4011 Oscilloscope Probe
- Attenuation = 1:10, Bandwidth = 350 MHz
- Maximum Voltage = 600V, Rise Time = 1ns
- With a 350MHz bandwidth, the 4011 is suitable for all but the very fastest Pico oscilloscope range

M5001 Oscilloscope Probe
- Attenuation = 1:10, Bandwidth = 500 MHz
- Maximum Voltage = 200V, Rise Time = 0.7ns
- This high stability 500MHz probe has a smaller probe and is much easier to use on high density PCBs.

PicoConnect 441 differential 1:1 probe
- General-purpose passive differential probe
- Measuring voltages on ranges from ±10 mV to ±50 V
- Used with the PicoScope 4444 only

DR7012 Oscilloscope Probe
- Attenuation = 1:1, Bandwidth = 950 MHz
- Maximum Voltage = 50V AC; 200V DC
- A demodulating probe, the 7012 output is a DC voltage equal to the peak to peak value of the measured waveform

PicoConnect 442 1000 V CAT III 25:1 differential probe
- 1000 V CAT III, passive differential probe
- 25:1 10 MHz voltage measurement
- Used with the PicoScope 4444 only

TA300 current probe 40 A AC/DC D9 connector
- 40 A AC/DC, 300 V CAT III
- 100 kHz current measurement
- Used with the PicoScope 4444 only

TA301 current probe 200/2000 A AC/DC D9 connector
- 200/2000 A AC/DC, 150 V CAT II
- 20 kHz current measurement probe
- Used with the PicoScope 4444 only

TA325 Flex current probe 3-phase 30/300/3000 A AC BNC
- Flexible 3-phase switched-range 30/300/3000 A AC RMS
- 1000 V CAT III, 10 Hz to 20 kHz current probe
- Used with the PicoScope 4444 only
- 3 x TA271 D9-BNC Adaptors required

TA326 Flex current probe 30/300/3000 A AC BNC
- Flexible single-phase switched-range 30/300/3000 A AC RMS
- 1000 V CAT III, 10 Hz to 20 kHz current probe
- Used with the PicoScope 4444 only

D9-BNC adaptor
- Suitable for ground-referenced measurements
- Essential when using the TA325 and TA326 current probes
- Used with the PicoScope 4444 only
PicoScope 3000E
4 Channel Oscilloscope Kits
- 3417E: 4 Channels
- 350 MHz with 5 GS/s
- 10 bit resolution (up to 14 bit with Enhanced Resolution)

D9-dual BNC adaptor
- Suitable for differential measurements using two single-ended probes
- Used with the PicoScope 4444 only

PicoScope 4444 carry case
- Hold the PicoConnect 4444 and its accessories
- Portable

PicoConnect RF, microwave and pulse passive probe
- Up to 5 GHz bandwidth
- Fits all SMA, K and PC3.5 50 Ω input ports
- Less than 70 ps transition time

PicoConnect gigabit passive probe
- High-speed logic voltage applications
- Less than 40 ps transition time
- Suited to Ethernet, USB3, HDMI, SATA, PCI, LVD and other high-speed cabled, chip to chip and backplane interfaces

PicoScope 6000E Series MSO pod, 8 channels
- 8 digital inputs per pod
- 500 MHz bandwidth, 1 Gb/s
- 5 GS/s sampling on 16 digital channels

A3136 1.3 GHz active oscilloscope probe
- High input impedance up to 1.3 GHz
- input resistance of 1 MΩ
- capacitance of 0.9 pF

A3076 750 MHz active oscilloscope probe
- High input impedance up to 750 MHz
- Input resistance of 1 MΩ
- Capacitance of 0.9 pF
PicoScope 4000 High-resolution deep-memory oscilloscope
- 2 channels (4 & 8 channels also available)
- 20 MHz bandwidth
- 256 MS capture memory

P2056 passive oscilloscope probe: 500 MHz
- 500 MHz Bandwidth

P2036 passive oscilloscope probe: 300 MHz
- 300 MHz Bandwidth
PicoScope 4262 16-bit high-resolution oscilloscope
- 2 Channels + External trigger & Arbitrary Waveform Generator
- 5 MHz Bandwidth, 10MS/s Sampling Rate
- 16MS Buffer Memory, 16 bits Resolution, 20 bits Enhanced Resolution
PicoScope 4444 kit
- Ideal for use in non-ground referenced measurements
PicoScope 4444 Oscilloscope
- 4 fully differential high-impedance inputs
- Measure differential signals with a single channel
- Choice of accessories for sensitive low-level, general electronic & 1000 V CAT III applications
PicoScope 5000 Series
- 2 Channels
- Flexible resolution from 8 to 16 bits
- 60 MHz analog bandwidth
PicoScope 6000E Series
- 4 channels
- 300MHz bandwidth
- 8-bit resolution
PicoScope 9400 Series
- 2 channels
- 5GHz bandwidth
- 250 KS Memory
PicoScope 9300 Series
- 2 channels
- 20GHz bandwidth
- Integrated TDR/TDT (60 ps / 2.5 to 7 V)