#PP799
PicoScope 4262 16-bit high-resolution oscilloscope
#PP799
PicoScope 4262 16-bit high-resolution oscilloscope
$2545.00*
*15% GST applicable for sales within NZ
Product Description
- 2 Channels
- 16-bit resolution
- Arbitrary waveform generator
- 5 MHz bandwidth
- 16 MS buffer memory
- Low distortion (96 dB SFDR)
- Low noise (8.5 µV RMS)
- USB powered
Most digital oscilloscopes have been designed for viewing fast digital signals. The trend has been to use new technology solely to increase sampling rate and bandwidth. With the PicoScope 4262, however, we have focused on what’s important for measuring analog signals: increasing the resolution, improving dynamic range, and reducing noise and distortion.
The result is an oscilloscope / FFT analyzer that has a level of performance to put most audio analyzers to shame yet has a 5 MHz bandwidth making it equally suitable for vibration and ultrasound signals as well as a wide range of precision measurement tasks.
Many applications such as vibration analysis require long captures at high sampling rates, which requires a deep capture memory. The PicoScope 4262 has a 16 million sample buffer memory so can capture at 10 MS/s for timebases as long as 100 ms/div. If you require longer times, the USB streaming mode can sample directly into PC memory.
Included in Kit




Specifications
Oscilloscope — vertical | |
---|---|
Input channels | 2 |
Bandwidth ±20 mV range ±10 mV range | 5 MHz 4 MHz 3 MHz |
Hardware bandwidth limiter | 200 kHz, switchable |
Rise time (calculated) ±20 mV range ±10 mV range | 70 ns 88 ns 117 ns |
Input type | Single-ended, BNC connector |
Vertical resolution | 16 bits |
Enhanced vertical resolution | 20 bits |
Input sensitivity | 2 mV/div to 4 V/div (10 vertical divisions) |
Input ranges (full scale) | ±10 mV to ±20 V in 11 ranges |
Input coupling | Software-selectable AC/DC |
Input characteristics | 1 MΩ ±2% || 15 pF ±2 pF |
DC accuracy (% of full scale) ±50 mV range ±20 mV range ±10 mV range | ±0.25% ±0.5% ±1% ±2% |
Overvoltage protection | ±50 V (DC + AC peak) |
Oscilloscope — horizontal | |||
---|---|---|---|
Maximum sampling rate (real-time) | 10 MS/s | ||
Maximum sampling rate (continuous streaming mode) Using PicoScope Using the SDK | 10 MS/s 10 MS/s one channel (PC-dependent) 6.7 MS/s two channels (PC-dependent) | ||
Timebase ranges | 1 µs/div to 5000 s/div | ||
Buffer memory | 16 MS shared between active channels | ||
Streaming buffer memory (PicoScope) | 100 MS (shared) | ||
Streaming buffer memory (SDK) | Up to available PC memory | ||
Maximum buffer segments (PicoScope) | 10,000 | ||
Maximum buffer segments (SDK) | 32,768 | ||
Maximum waveforms per second | 9,100 (typical) | ||
Timebase accuracy | ±50 ppm | ||
Sample jitter | < 10 ps RMS |
Dynamic performance (typical) | |
---|---|
Crosstalk | > 50,000:1 |
Harmonic distortion | –95 dB typical @ 10 kHz, –1 dBfs input |
SFDR | 96 dB typical @ 10 kHz, –1 dBfs input |
Noise | 8.5 µV RMS (on most sensitive range) |
Bandwidth flatness | [+0.25 dB, –3 dB] from DC to full bandwidth |
Pulse response | < 1% overshoot on all ranges |
Triggering (general) | |
---|---|
Trigger modes | Free run, auto, repeat, single, rapid (segmented memory) |
Maximum pre–trigger capture | Up to 100% of capture size |
Maximum post–trigger delay | Up to 4 billion samples |
Trigger rearm time | < 10 µs on fastest timebase |
Triggering (main inputs) | |||||
---|---|---|---|---|---|
Source | Ch A, Ch B | ||||
Trigger types | Rising, falling, adjustable hysteresis, window, pulse width, window pulse width, dropout, window dropout, interval, logic, runt pulse | ||||
Trigger level | Adjustable over whole of selected voltage range | ||||
Trigger sensitivity | Digital triggering provides 1 LSB accuracy up to full bandwidth of scope | ||||
Maximum pre–trigger capture | Up to 100% of capture size | ||||
Maximum post–trigger delay | Up to 4 billion samples | ||||
Trigger rearm time | < 10 µs on fastest timebase |
External trigger input | |
---|---|
Trigger types | Edge, pulse width, dropout, interval, logic, delayed |
Input characteristics | 1 MΩ ±2% || 15 pF ±2 pF |
Input type | Rear-panel BNC connector |
Threshold range | ±5 V and ±500 mV, DC coupled |
Sensitivity | 25 mV p-p at 1 MHz, typical |
DC accuracy | ±1% of full scale |
Bandwidth | 5 MHz |
Overvoltage protection | ±50 V |
Signal generator | |
---|---|
Standard output signals | Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half–sine, white noise, PRBS |
Standard signal frequency | DC to 20 kHz |
Sweep modes | Up, down, dual |
Frequency accuracy | ±50 ppm |
Frequency resolution | < 0.01 Hz |
Voltage range | ±1 V (no load) |
Amplitude and offset adjustment | 100 µV steps (within overall ±1 V range) |
Amplitude flatness | < 0.1 dB to 20 kHz, typical |
DC accuracy | ±0.5% of full scale |
SFDR | 102 dB typical @ 10 kHz, -1 dBfs input |
Connector type | Front-panel BNC |
Output characteristics | 600 Ω |
Overvoltage protection | ±10 V |
Arbitrary waveform generator | |
---|---|
Update rate | 192 kS/s |
Buffer size | 4 096 samples |
Resolution | 16 bits |
Bandwidth | 20 kHz |
Rise time (10% to 90%) | 11 µs, typical |
Spectrum analyzer | ||
---|---|---|
Frequency range | DC to 5 MHz | |
Display modes | Magnitude, peak hold, average | |
Windowing functions | Rectangular, Gaussian, triangular, Blackman, Blackman–Harris, Hamming, Hann, flat–top | |
Number of FFT points | Selectable from 128 to 1 million in powers of 2 | |
Scale / units | X axis : linear or log 10 Y axis : logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts) |
Math channels | |||||
---|---|---|---|---|---|
Functions | −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, freq, derivative, integral, min, max, average, peak, delay | ||||
Operands | A, B (input channels), T (time), reference waveforms, constants, Pi |
Automatic measurements | |||||
---|---|---|---|---|---|
Oscilloscope mode | AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate. | ||||
Spectrum mode | Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD plus noise, SFDR, SINAD, SNR, IMD | ||||
Statistics | Minimum, maximum, average and standard deviation |
Serial decoding | |||||
---|---|---|---|---|---|
Protocols | 1-Wire, ARINC 429, CAN, DALI, DCC, DMX512, I²C, LIN, Manchester, PS/2, SENT, SPI, UART/RS-232, USB 1.0 | ||||
Inputs | All input channels with any mixture of protocols |
Mask limit testing | |
---|---|
Mask generation | Auto generate from captured waveform, manual drawing, manual coordinate entry |
Actions | Highlight on screen, select in buffer overview, activate alarm |
Statistics | Pass/fail, failure count, total count |
Alarms | |
---|---|
Initiating events | Capture, buffer full, mask fail |
Alarm actions | Beep, play sound, stop/restart capture, run executable, save current buffer/all buffers, trigger signal generator |
Display | |||||
---|---|---|---|---|---|
Interpolation | Linear or sin(x)/x | ||||
Persistence modes | Digital color, analog intensity, fast, custom |
Data export | |
---|---|
Output file formats | BMP, CSV, GIF, JPG, MATLAB 4, PDF, PNG, PicoScope data, PicoScope settings, TXT |
Output functions | Copy to clipboard, print |
Environmental | ||
---|---|---|
Temperature range (operating) | 0 °C to 45 °C | |
Temperature range (stated accuracy) | 20 °C to 30 °C | |
Temperature range (storage) | –20 °C to +60 °C | |
Humidity range (operating) | 5% to 80% RH non-condensing | |
Humidity range (storage) | 5% to 95% RH non-condensing |
Physical properties | |
---|---|
Dimensions (including connectors) | 210 x 135 x 40 mm (approx 8.2 x 5.3 x 1.5 in) |
Weight | < 500 g (approx 1.1 lb) |
Software | ||
---|---|---|
Windows software | PicoScope for Windows | |
macOS software | PicoScope for macOS Software development kit (SDK) OS versions: see release notes | |
Linux software | PicoScope for Linux Software development kit (SDK) See Linux Software & Drivers for details of supported distributions | |
Languages | Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish |
General | |
---|---|
Additional hardware (supplied) | 2 x TA375 probes, USB 2.0 cable, user manuals |
PC connectivity | USB 2.0 (compatible with USB 1.1 and USB 3.0; USB 1.1 not recommended) |
Power requirements | Powered from USB port |
Safety approvals | European LVD standard |
EMC approvals | European EMC standard |
Environmental approvals | RoHS compliant |
Total satisfaction guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. |